    • Due to unforeseen circumstances, our phone line will be unavailable from 5pm to 9pm GMT on Thursday, 28th March. Please be assured that orders will continue to be processed as usual during this period. For any queries, you can still contact us through your customer portal, where our team will be ready to assist you.

      March 28, 2024

  • Sign In

Disclaimer: This is an example of a student written essay.
Click here for sample essays written by our professional writers.

Any scientific information contained within this essay should not be treated as fact, this content is to be used for educational purposes only and may contain factual inaccuracies or be out of date.

Components of the RankineCycler Steam Turbine Power System

Paper Type: Free Essay Subject: Engineering
Wordcount: 3615 words Published: 18th May 2020

Reference this

Abstract

The main objective of this experiment is to become familiar with the primary components of the RankineCycler Steam Turbine Power System. Another objective of this experiment is to understand and be able to analyze the Rankine cycle. In the Rankine cycle, there are four main components. These components include the pump, the boiler, the turbine, and the condenser. In this module, the procedure given to operate this apparatus was discussed. The different types of boilers and turbines used in power plants and their advantages and disadvantages were explored. Lastly, some light numerical calculations were performed to analyze the components of the Rankine Cycler system.

 

Theory

The Rankine cycle is the most common thermodynamic cycle used in electricity generation in the United States. In a Rankine cycle, steam is the working fluid. There are four main components in a Rankine cycle. These components consist of a pump, boiler, turbine, and condenser. The Rankine cycle begins in the boiler in which water is heated to a high temperature and high pressure steam. This steam then enters the turbine, where it expands and turns the blades of the turbine. The turbine shaft, which is connected to a generator, rotates and produces electricity. The steam then exits the turbine and enters the condenser at a much lower temperature and pressure. The condenser than condenses the steam back into a saturated liquid. The water then leaves the condenser and pumped back to the boiler, where the process starts again. A schematic of the four component Rankine cycle is shown below in Figure 1.

Figure 1. Four component Rankine cycle that a power plant operates on.

This basic, four component Rankine cycle is rarely used in application, and instead, a more complicated cycle is used.  In the case of a power plant, components such as feed water heater and multiple steps in both the turbine as well as multiple turbines. In general, a power plant is named after its energy source. For example, a nuclear power plant’s heat source is a nuclear reactor. To properly analyze the Rankine cycle, the energy of each main component is considered. For this purpose, a thermodynamic property of a system called enthalpy is used. Enthalpy is described as the summation of a system’s internal energy and the pressure and volume. In this experiment, the Rankine Cycler Steam Turbine Power Steam will be studied. In this system, it should be noted that there is no physical pump. Instead, the water reservoir sits at an elevated height above the boiler so the water is fed to it due to the gravitational potential difference. For this model power plant, liquid propane is the heat source. Liquid propane is advantageous to use since it has 2.5 times higher energy than natural gas. The boiler used in this system is a shell and tube configuration in which flames pass through the tubes to heat the water. The pressure value is mounted on top of the boiler and the water level is shown on the site gauge. The boiler is connected to the turbine by the steam admission valve. The steam admission valve can be adjusted to control the flow rate of the steam, which turns the blades of the turbine. Figure 1 shows a detailed view of the turbine mechanism.

Procedure

An image of the Rankine Cycler apparatus with all parts labeled are shown below in Figure 2.

Figure 2 — Rankine Cycler apparatus with labeled components.

 A summary and step by step guide detailing the procedures to operate the Rankine Cycler are shown below:

Pre-Start:

  1. The area surrounding the Rankine Cycler is safe to operate.
  2. The wheels of the Rankine Cycler should then be locked to prevent the apparatus from rolling during operation.
  3. Turn the keyed master switch to the off position.
  4. Ensure that the burner switch is in the off position.
  5. The load switch should be set to the off position.
  6. Set the rheostat to the minimum load by turning it fully counterclockwise.
  7. The operator panel gas valve should then be set to the off position.
  8. The condenser tower should be drained of any residual fluid.
  9. The front and back doors of the boiler should both be closed and latched.
  10. The steam admission should be turned so it is fully open.
  11. It should be ensured that the condenser tower is drained completely.
  12. The drain clamp on the condenser tower should then be clamped.
  13. The boiler should then be filled, which can be achieved by filling the beaker with 6000 mL and opening the drain clamp.
  14. Once the boiler has been completely filled, store the fill beaker for later use.
  15. The steam admission valve should then be closed.
  16. The Rankine power cable should then be connected.
  17. Ensure the Rankine Cycler is effectively communicating with the computer.
  18. Ensure that the propane tank is connected.

Start and Operation:

  1. The propane tank should be opened.
  2. Turn the gas valve located on the Rankine Cycler on.
  3. Listen and smell for any propane gas leaks in the tank. If none are detected, proceed with the following steps.
  4. Turn the keyed master switch to the on position, which can be verified by illumination of the green panel light.
  5. Open the program on the computer used to begin collecting data.
  6. The burner switch should then be turned on, which can be verified by illumination of the red panel light.  At this time, the motor in the boiler should begin rotating.
  7. Allow about 110 psig of pressure to build within the system (this should take approximately 5-10 minutes). At this point, small vapor leaks and condensation within the turbine may occur. This behavior is considered normal.
  8. Slowly open the steam admission valve until the pressure reaches approximately 40 psig.
  9. Close the steam admission valve and once again allow the pressure to reach 110 psig.
  10. Slowly open the steam admission valve until the pressure reaches approximately 40 psig.
  11. Close the steam admission valve and allow the pressure to once again build back to 110 psig.

Data Collection:

  1. Slowly open the steam admission valve, ensuring that the voltage doesn’t exceed 15 V.
  2. Turn the load switch to the on position.
  3. Using the load control and steam admission valve, adjust the values in order to achieve steady state. These values should be approximately 6 V, 0.2 Amps, and 110 psig.
  4. Once steady state has been reached, set the site upper bezel to the current water level and note the start time.
  5. Run the experiment for 5-10 minutes.
  6. It should be ensured that the water level never falls below 2.5 cm on the site glass.
  7. At the end of the trial, place the cite lower bezel to the current water level.
  8. End the trial, note the time, and save the data.

Shutdown:

  1. Set the burner switch to the off position and verify that the red light turns off.
  2. Allow the boiler to cool down for a few minutes before proceeding to the next steps.
  3. Fully close the steam admission valve.
  4. The operator penal gas valve should then be turned off.
  5. The load rheostat should then be turned fully counterclockwise.
  6. The load switch should then be set to the off position.
  7. The master key should then be turned off.
  8. The steam admission valve should then be slowly opened to release any remaining pressure. This should be done slowly to prevent the turbine from rotating too rapidly.
  9. The fuel source should then be turned off.
  10. After the system has completely cooled, drain the condenser tower and record the volume of water.
  11. Fill the boiler with distilled water to the same level as the site upper bezel, then empty it to the point where the site lower bezel is. Record this value.

 

Discussion

The flow schematic of the basic Rankine cycle is shown above in Figure 1. The different processes at each point in the Rankine cycle are below in Figure 3.

Figure 3 — The relationship between temperature and entropy in a simple steam power plant.

In Figure 3, it can be seen that there are four main processes. From steps 1-2, there is a reversible adiabatic (no heat transfer) process in the pump. From steps 2-3, constant pressure heat transfer occurs in the boiler. From steps 3-4, a reversible adiabatic expansion occurs within the turbine. From step 4-1, a constant pressure heat transfer occurs in the condenser. It should be noted that the liquid can be heated to a superheated state, as shown in the cycle 1-2-3’-4’-1. If the kinetic and potential in the system can be assumed negligible, the heat transferred to the fluid can be represented as the area underneath a-2-2’-3-b-a. The heat transferred from the fluid may be represented as the area underneath a-1-4-b-a [1].

Get Help With Your Essay

If you need assistance with writing your essay, our professional essay writing service is here to help!

Essay Writing Service

A turbine is a rotating component that produces work, and therefore, power, at the expense of the working fluid’s pressure [1]. There are many different types of turbines that can be used in a power plant. The turbines that can be included in a power plants include a gas turbine, steam turbine, or water turbine. A steam turbine is the type that is used in the Rankine Cycler. A steam turbine has many advantages and disadvantages. The advantages of a steam turbine include high thermal efficiency, a high power to weight ratio, and also have less moving parts than other alternatives. Steam turbines also contain a lot of enthalpy and are more reliable than alternatives. However, there are many disadvantages of using steam turbines. These disadvantages include a high cost of operation and a long time to startup.

A boiler is a closed chamber that is used to heat fluids, usually water. This fluid is usually brought to a temperature and pressure that causes the fluid to become a vapor. There are many types of boilers that can be used in a power plant depending on the type of power plant. For a solid fuel power plant, a grate boiler, a fuel boiler, or a bed boiler can be used. For a nuclear power plant, a water boiler or a gas-cooled boiler can be used. The type of boiler that is used in the Rankine Cycler is a bed boiler in which propane is the fuel source. In the boiler, water enters and is then heated to a superheated state. The boiler configuration is a fire tube, in which fire heats the water inside the boiler. Boilers that use propane as the fuel source are advantageous because it has higher energy density than other fuel alternatives. Due to this, propane as a fuel source is efficient. However, propane can be disadvantageous to use because it is not environmentally safe and it is relatively expensive compared with other fuel source alternatives. The energy content per unit volume of liquid propane is 95, 067 kJ/m3 [3].

The most noticeable difference between the standard rankine cycle and the Rankine Cycler is that the pump component of the rankine cycle is not included in the Rankine Cycler. To account for this, the reservoir that supplies water to the condenser tower is placed at a higher elevation. Therefore, water will enter into the system due to gravitational difference rather than being pumped from a lower elevation to a higher elevation. Because the work done by the pump is much less compared to the work done by the turbine, the pump contribution can be neglected when calculating the net work of the system. Another notable difference is the fact that the Rankine Cycler is not a closed, continuous process, while the rankine cycle is. In the standard rankine cycle, the liquid that is produced in the condenser step is then pumped back into the boiler. This part is not included in the Rankine Cycler because measurements must be taken regarding the mass of the water. This discrepancy is accounted for by supplying the system with a known amount of water, and having indications on the apparatus when the water runs low.

It is very important to preheat the system. Preheating the system allows the steam lines, valves, and turbine to reach the adequate operating temperatures. It is also important to ensure that the water level of the boiler does not fall below 25 mm mark on the site glass. The boiler and burner may experience serious damage if the water level of the boiler falls beneath this point. 

It is given that the system flow meter measures gaseous liquid propane (LP) flow rate to be 6 L/min. The steady state energy consumption per hour can then be determined by using the energy content of liquid propane from the following calculation:

Energy consumption per hour=(6 Lmin)(m31000 L)(95,067 kJ m3)(60 min hr)=34,244kJhr

 

The boiler is a shell and tube type configuration. This configuration can be shown below in Figure 4.

Figure 4 — Schematic of the shell and tube configuration of the boiler.

It can be seen from Figure 4 that there are 17 smaller tubes and one main flame tube. The geometries of the boiler are shown in the Appendix. To determine the available volume for water in the boiler, the total internal volume of the boiler is first calculated. This calculation is shown below:

Net internal volume of the boiler=πr2L=π[20.32 cm 2(0.198 cm)2]2[29.85 cm2(0.198 cm)]=9185 cm3

The volume of the flame tubes are then calculated:

Volume of main tube=πr2L=π(5.08 cm2)2(29.85 cm)=605 cm3

Volume of the small tubes=πr2L=π(1.90 cm2)2(28.85 cm)(17)=1439 cm3 

Finally, the net internal volume of the boiler can then be calculated by:

Net internal volume=9185 cm(605 cm+1439 cm)=7141 cm3=7141 mL

Therefore, there is 7141 mL of available volume for the water to flow. If the boiler is filled with 6000 mL, there will be 1141 mL of unoccupied space. The calculation to obtain the water level is shown below.

6000 mL7141 mL=0.84

(0.84)[20.32 cm2(0.198 cm)]=16.74 cm

The location of the water is shown below in Figure 5.

Figure 5 — Schematic of the water level if 6000 mL of water are added to the boiler.

It can be seen from Figure 5 that all of the tubes will be covered with water except the top two tubes which will be partially covered.

References

[1] thermo book

[2] https://www.nuclear-power.net/nuclear-power-plant/turbine-generator-power-conversion-system/what-is-steam-turbine-description-and-characteristics/advantages-and-disadvantages-of-steam-turbines/https://www.nsenergybusiness.com/features/newsmajor-types-of-power-plants-to-generate-energy-151217-6004336y/

[3] https://www.engineeringtoolbox.com/energy-content-d_868.html

 

Cite This Work

To export a reference to this article please select a referencing stye below:

Reference Copied to Clipboard.
Reference Copied to Clipboard.
Reference Copied to Clipboard.
Reference Copied to Clipboard.
Reference Copied to Clipboard.
Reference Copied to Clipboard.
Reference Copied to Clipboard.

Related Services

View all

DMCA / Removal Request

If you are the original writer of this essay and no longer wish to have your work published on UKEssays.com then please: